Find the leak before choosing the fix

Air Sealing Your Home

Find unwanted air leaks, choose the right seal and keep the ventilation your home needs. A practical starting point for reducing draughts.

In this guide

Two different jobs

What is air sealing?

Air sealing reduces unwanted air movement through gaps in a building. Draught proofing is the same practical goal: control unintended leaks while maintaining the fresh-air routes the home needs.

Insulation slows heat transfer through a building element. Air sealing addresses air passing through an opening. A room can have insulation and still feel draughty if air can move around a poorly sealed door, window or ceiling hatch.

This is why air sealing and insulation work together. Pushing a piece of fibrous insulation into a gap does not automatically create an airtight joint. Equally, sealing a crack does not add the thermal resistance of a specified insulation layer. Our guide to how insulation works explains the wider heat-flow question.

A cold surface is not always an air leak. If there is no identifiable airflow, missing insulation or a conductive connection may be involved. Our thermal-bridging guide explains that different heat path.

Start with a room-by-room check

How to find air leaks in your home

Begin with the places you can inspect from a stable, accessible position. Keep a short list of the rooms affected, the conditions when you notice the draught and the exact joint that seems to be leaking. This helps distinguish a repairable opening from a general feeling of cold.

  1. Check closed doors and windows. Look for damaged seals, daylight around an edge, rattling or a leaf that no longer closes evenly. Check the fixed frame-to-wall joint separately from the opening part.
  2. Look at accessible junctions. Check visible skirting and lining joints, the edge of a ceiling hatch and service penetrations. Note the location rather than filling every opening immediately.
  3. Check whether the opening has a purpose. Identify ventilation grilles, window drainage holes and appliance air supplies before choosing a repair.
  4. Record anything concealed or uncertain. A visible gap may connect to a larger hidden path. Photograph it for the relevant installer or building professional instead of dismantling electrical fittings or entering an unsafe roof space.

A visual distinction

Control the leak. Keep the ventilation.

Unwanted leakage

Outside air
Gap in a joint
Room

Air moves through an unintended opening.

Find the gap and use an appropriate sealing detail.

Planned ventilation

Outside air
Designed air supply
Room

Fresh air enters through a planned route.

Maintain the ventilation required by the home and its appliances.

A schematic showing two kinds of air path, not a complete ventilation design. Pressure and weather can change airflow direction; extract ventilation provides another planned route out.

A walk-through can reveal obvious defects, but it cannot quantify the home’s total leakage. Avoid using a naked flame to find draughts. For unclear or widespread problems, a suitable professional assessment can help establish the next step.

Match the material to the work

Caulk, weatherstripping or foam?

These products are not interchangeable. A seal that works around a fixed frame may stop a moving sash from opening; a thick strip can prevent a door from latching. Establish how the joint works before buying a product.

Choose by the joint, not just the product name

What kind of gap are you treating?

01

Does the joint stay fixed?

Consider a compatible sealant

For a suitable stationary frame-to-wall or lining joint, choose a sealant system that suits the surfaces, joint dimensions, exposure and expected movement.

02

Does the part open or slide?

Consider a suitable weather seal

Weatherstripping, brush seals or door-bottom seals can treat appropriate moving edges. Match the profile and compression to the actual gap so the part still closes properly.

03

Is the detail large or specialised?

Get the detail checked first

Large voids, concealed connections, fire-rated construction, electrical work and hot flues need an appropriate system and competent installation rather than a generic filler.

A selection guide for discussing the job. Product compatibility, preparation, joint size and installation requirements still need to be checked against the manufacturer’s instructions.

Where does expanding foam fit?

Some specified frame-to-opening details use a suitable low-expansion foam. Use a product intended for that application and follow its gap-size, curing and finishing instructions. It is not a universal repair for every hole, moving joint or heat-exposed opening. Where a gap needs backing, protection or fire performance, resolve the complete detail first.

For an accessible replacement weather seal, compare the existing profile and the actual gap. Check the surface condition, preparation instructions and whether the new seal permits smooth opening, closing and locking. A temporary draught excluder may reduce a floor-level draught, but it does not repair an uneven frame or the gaps around its sides.

Look at the actual connection

Draught proofing common leak points

Check the function before sealing an opening
LocationWhat to checkWhat to preserve
DoorsCheck the perimeter seal, threshold and whether the door closes squarely. Use a suitable replacement seal or repair the alignment as appropriate.Do not obstruct opening, locking, drainage or a required air supply.
WindowsDistinguish the moving sash seal from the stationary frame-to-wall joint. Identify worn seals and repair defects before assuming replacement glazing is needed.Keep designed drainage outlets and opening mechanisms functional.
Ceiling accessCheck the hatch perimeter and whether the hatch sits correctly. Treat the room-to-roof-space boundary as a defined detail.Keep safe access and required clearances. Do not block roof ventilation to treat a room-side leak.
Services and junctionsRecord visible gaps around pipes, cables and lining joints; identify the construction and required sealing system.Electrical fittings, hot penetrations and fire-rated elements need the relevant competent trade or specified system.

Air leakage is one part of a window’s thermal performance. Glass, frames, shading and coverings have different roles. Use our window-insulation guide for the wider upgrade choices and our double-glazing guide when comparing glazing systems.

If insulation above a ceiling has also been disturbed, assess its coverage separately from the air seal. Our insulation-installation guide covers preparation and fitting considerations. The two jobs should be coordinated, including any electrical work.

Reduce uncontrolled airflow

Should you seal air vents?

Do not seal an opening until you know what it does. Designed ventilation, appliance air supplies and drainage routes must be distinguished from unintended gaps.

Airtightness controls unwanted air movement; ventilation provides deliberate air exchange. Sealing more leaks does not automatically mean better indoor air quality. The home still needs a suitable way to remove indoor moisture and pollutants and provide fresh air.

Where fuel-burning appliances or fireplaces are present, have their combustion-air and ventilation needs considered before changing the air supply. Generic foam or sealant is not a substitute for an appropriate flue, appliance or fire-stopping detail.

Condensation needs its own investigation. Air sealing may be one part of an improvement, but it does not repair a roof leak or resolve every moisture problem. Our moisture-control guide explains how sources of water, humidity and surface conditions fit together.

Make the scope clear

Testing, costs and checking the result

When is a blower-door test useful?

A calibrated blower-door test uses a fan and pressure measurements to quantify building air leakage under test conditions. Combined with a suitable inspection, it can help locate less obvious paths and compare results before and after work. It measures airtightness, rather than the R-value of insulation.

Thermal imaging shows surface-temperature patterns and can support an assessment under suitable conditions. It needs interpretation: a cold pattern is not automatically proof of an air leak. Ask the assessor what each test can establish and how its findings will inform the repair.

What affects the cost of air sealing?

Cost depends on the number and type of defects, access, repairs to frames or finishes, the specified sealing system and whether testing is included. Replacing one accessible weather strip and treating concealed junctions are different scopes. There is no useful single price for every home.

  • Ask for the locations and defects to be identified. Establish which openings will be treated and which must remain functional.
  • Confirm the materials and preparation. Include removal of failed seals, substrate repairs and finishing where required.
  • Agree how the work will be checked. Confirm door and window operation, visible continuity and any specified testing.
  • Keep the record. Save product details and photographs so future maintenance starts with the correct information.

If you are coordinating a wider renovation, use our existing-home insulation guide to plan the sequence. For a new build, plan the insulation and related checks before work is concealed.

Common questions

Plan the next step with confidence

Is draught proofing the same as air sealing?

The terms describe reducing unwanted air leakage. Draught proofing often refers to accessible gaps around doors and windows; air sealing can also include less visible joints and penetrations across the building boundary.

Can insulation stop a draught?

Insulation and an air seal do different jobs. A correctly fitted insulating layer can still have an air-leak path around it. Find the unintended opening and choose a suitable sealing detail rather than assuming that adding more insulation will seal it.

Should I use caulk or weatherstripping?

It depends on the joint. Suitable sealant can treat some stationary joints; an opening sash or door edge generally needs an appropriate moving-edge seal. Check the gap, materials and manufacturer’s instructions before choosing.

Can I make a room completely airtight?

The practical aim is controlled airflow with suitable ventilation, not simply closing every opening. Identify the room’s ventilation and appliance requirements before changing them.

Do I need a blower-door test for a worn door seal?

An obvious local defect can often be inspected directly. Testing can be useful when the problem is widespread, hidden or needs quantified checking. Ask for an assessment proportionate to the work.

Will air sealing fix condensation?

Not by itself in every case. Condensation depends on moisture, ventilation and surface temperatures. Investigate the cause and make sure a sealing change does not remove needed ventilation.

Will draught proofing reduce my electricity bill?

It can reduce unwanted air exchange and the associated heating or cooling demand. The effect on your bill depends on the leakage treated, climate and how you use heating and cooling; no fixed saving applies to every home.

Sources & further reading

Local background: TIPSASA’s retrofit guide, section 8.3. General technical references: YourHome: ventilation and airtightness; the US Department of Energy’s air-sealing consumer guide, home energy assessment guide and window-opening air-sealing guidance. Overseas requirements are not South African rules. Use the applicable project detail and product instructions. Reviewed November 2026.

Bring the improvements together

Plan the insulation.
Improve everyday comfort.

Talk to Home Insulations about product supply and installation for your home.