Look beyond the insulation between the supports

Thermal Bridging Explained

Understand how heat travels through a building’s structure, why cold spots need investigation and what makes an effective improvement.

In this guide

A route through the structure

What is thermal bridging?

Thermal bridging occurs where part of a building provides an easier route for heat transfer than the surrounding insulated construction. A stud, beam or slab edge can conduct heat across the insulating layer, reducing the performance of the whole assembly.

Picture insulation fitted between framing members. Heat can pass through both the insulation and the framing; filling the spaces does not remove the route through the supports. Steel conducts heat particularly readily. Timber can also bridge an insulating layer, even though it is less conductive than steel.

“Cold bridging” describes the same issue. Heat still moves from the warmer side towards the cooler side: out of a heated home in winter, or towards a cooled room when the outside is hotter. The direction depends on the temperature difference, not the name of the material.

A product’s declared R-value describes that product at its stated thickness. It does not automatically describe the finished wall or ceiling. Read our U-value guide for the difference between a material rating and an assembly’s heat transfer.

Follow the insulating layer

Where do thermal bridges occur?

Look at places where the insulating layer is interrupted by structure or changes direction. The important question is whether the detail connects areas at different temperatures, rather than whether a beam or concrete element exists somewhere in the house.

A simplified section through a framed assembly

Insulation between supports leaves another heat path.

Between the framing

Warmer side
Insulation
Framing
Insulation
Framing crosses the insulating layer
Cooler side

Heat can take a more conductive route through the framing.

Across the framing too

Warmer side
Insulation
Framing
Insulation
Continuous insulating layer
Cooler side

An added layer crosses the framing route and increases its resistance.

The arrow follows heat through the framing from warm to cool. The comparison shows a principle, not a measured heat-flow rate or a complete construction detail. Fixings and junctions still need attention in the second arrangement.

Ceiling and roof framing

Where insulation sits only between joists or other framing, those members provide a parallel heat path. A roof assembly with metal supports has its own connection details to consider. Exposed edges, access hatches and wall-to-roof junctions also deserve inspection. They may involve bridging, incomplete coverage or more than one issue.

Do not assume another roll placed anywhere in the roof will solve a framing bridge. Its position and continuity matter. See our guide to adding insulation over an existing layer before planning a top-up.

Walls, openings and floor edges

Repeated studs can create repeated bridges. A slab edge, projecting balcony or beam crossing the insulated boundary can create a local or junction bridge. Window performance also depends on the frame: a thermally broken frame interrupts a conductive route, while double glazing describes the glazing configuration.

For the wider installation options, use our wall-insulation guide, our floor-insulation guide or our double-glazing guide.

Choose the right remedy

Thermal bridging is different from a draught

A solid conductive connection can transfer heat even when the surrounding construction is airtight. Conversely, a draught can occur where insulation is present but the air barrier has an opening. These issues can coexist, but one repair does not automatically fix the other.

Similar symptoms can require different work
IssueWhat happensWhat to investigate
Conductive bridgeHeat travels through a more conductive part of the assembly, such as a framing member.Assess continuity, the frame or junction detail, and whether an appropriate thermal break is possible.
Missing or displaced insulationAn area lacks the intended insulation coverage.Restore the specified coverage while retaining required clearances and ventilation.
Uncontrolled air leakageAir moves through a gap in the air barrier, often felt as a draught.Find and seal the unintended air path with a suitable detail; retain planned ventilation.

Sealant around a connection may stop air moving through a crack; it does not necessarily interrupt conduction through the solid member. Likewise, fitting fibrous insulation into a gap is not automatically an air seal. Our air-sealing guide covers that separate task.

Investigate before covering the symptom

How can you identify thermal bridging?

Start with the pattern and construction history. Does a cold area follow framing lines, a slab edge or a junction? Is there a noticeable draught? Did it appear after a leak or building alteration? Record the room, weather, heating or cooling use and whether the problem changes with conditions.

  • Inspect accessible details. Check the insulation position, visible interruptions and the junctions shown on the building plans. Record what can actually be seen.
  • Use thermal imaging in context. An infrared image shows surface-temperature patterns. An assessor must consider weather, temperature difference, surface properties and other possible causes before identifying a bridge.
  • Separate airtightness testing. A calibrated blower-door test measures air leakage. It can support an investigation alongside other inspections; it does not measure a solid member’s thermal bridge directly.
  • Assess concealed or complex junctions. The responsible designer may need drawings and a thermal calculation or model to evaluate the detail and proposed repair.

A cooler internal surface can increase condensation risk when its temperature falls below the dew point of the room air. Damp marks alone do not establish thermal bridging: water entry, indoor moisture and ventilation also need checking. Begin with our moisture and condensation guide if dampness is the main symptom.

Improve the path that is causing the loss

How do you reduce thermal bridging?

The remedy should address the identified route. Common approaches include insulation that continues over framing, suitable thermal breaks at conductive connections, and better coordination of junctions during design. Increasing the insulation between supports can help that part of an assembly while leaving the framing route in place.

Three parts of the improvement plan

Trace the path. Improve the detail. Check the interfaces.

01

Continue the insulation

An appropriately designed layer across the framing can reduce the conductive bypass. It needs continuity at edges and junctions, with suitable fixing, fire and moisture details.

02

Interrupt the conductive connection

A thermal break introduces an appropriate less-conductive component into a connection. The product and detail must suit the load and system; structural connections need engineered solutions.

03

Resolve the complete assembly

Coordinate insulation, air control, moisture management and finishes. A change to one layer can affect the rest of the construction, so review the proposed build-up together.

Conceptual approaches to discuss with the project designer and installer. There is no universal board thickness, spacer or membrane position suitable for every building.

What does a thermal break do?

It adds thermal resistance where heat would otherwise pass through a conductive connection. Examples include a purpose-designed component within a window frame or an engineered structural connection. A strip of an arbitrary material is not a substitute for a tested or designed system.

Can reflective foil solve the problem?

A reflective surface controls radiant exchange when used with the required air space. Its presence does not by itself interrupt a steel or concrete path. Check the complete system’s declared performance and installation detail rather than assuming that a foil finish provides a conductive thermal break.

Keep product selection tied to the intended use. Our insulation types guide helps compare material roles; a product name alone does not establish a solution for a particular junction.

Make a repair proposal specific

What should you ask before paying for an improvement?

  1. What is the evidence for the diagnosis? Ask which observations support bridging and which alternatives were checked.
  2. Where is the heat path? Ask for the affected member or junction to be identified on a sketch or photograph.
  3. How will the proposal change that path? Establish where the insulating layer or thermal break will go and how it meets adjacent work.
  4. What else must the detail preserve? Resolve structural support, moisture control, fire performance, service clearances and designed ventilation.
  5. What is included in the quote? Separate investigation, access, materials, installation, finishing and checks before concealed work is covered.

There is no reliable single repair price per square metre for all thermal bridges. A local access-hatch issue and a projecting concrete balcony involve different investigations and trades. Ask for an itemised scope for the actual defect rather than budgeting from a generic insulation-roll price.

A renovation can create an opportunity to address a concealed junction while finishes are open. Our existing-home upgrade guide covers project planning. For local specification and compliance questions, consult our SANS 10400-XA guide and the professional responsible for the project.

Common questions

Get clear on the next step

Is cold bridging the same as thermal bridging?

Yes. Cold bridging is another name for the same heat-transfer issue. A cold internal patch in winter reflects heat moving towards a colder part of the construction; cold itself is not flowing through the wall.

Can thermal bridging cause condensation?

It can lower an internal surface temperature enough for condensation under suitable humidity and temperature conditions. It is one possible contributor, so investigate moisture sources, ventilation and water entry as well.

Will thicker insulation between joists stop a thermal bridge?

It can reduce heat transfer through the insulated areas, but the joist or framing path can remain. Whether an additional layer can safely cross that framing depends on the installation and complete construction detail.

Does every steel beam need to be covered with insulation?

No single rule covers every beam. Its position relative to the insulated boundary and temperatures on either side determines the thermal issue. Any treatment must preserve the required structural and fire performance.

Can a thermal camera prove the cause of a cold spot?

A camera records surface-temperature patterns. It can help locate areas for investigation, but interpretation and corroborating checks are needed to distinguish bridging from air leakage, missing insulation or moisture-related effects.

Will correcting a thermal bridge guarantee lower electricity bills?

No. It can improve the assembly’s thermal performance, but the effect on bills depends on the scale of the bridge, climate, the rest of the building and how heating or cooling is used.

Sources & further reading

Technical background: YourHome: insulation and thermal bridging; US Department of Energy: continuous exterior insulation; AIA: building-performance definitions; and the Department of Energy’s guide to home energy assessments. These explain general principles; overseas construction requirements are not South African requirements. Reviewed November 2026.